The air purification sterilizer (nucleic acid aerosol pollution removal instrument) is specially used to remove aerosol DNA / RNA in the laboratory air,
and can also sterilize the space area where the microbial limit is required, which can directly kill bacteria, fungi, viruses, etc. Species of microorganisms.
Qualifica del prodotto
CE Certification/ Test Report-NC1001/ Test Report/ New product and new technology appraisal and acceptance certificate/Electrical safety report/ Disinfection Products Record/ Hygiene License/ ISO 13485 Certificate-MDSAP/ ISO 9001 Certificate/ ISO 45001 Certificate/ ISO 14001 Certificate/ IPMS Certificate/ Verified Supplier Certificate
1. Removal of aerosol DNA / RNA in the air, the removal efficiency reaches more than 99%.
2. No need for air compressor to avoid huge noise.
3. The product adopts a specially designed industrial-grade dispersion system, the diameter of nano-micron liquid beads is ≤5μm.
4. Equipped with HEPA high-efficiency filter to remove residual viruses, bacteria, DNA, RNA and residual reagents effectively in the air.
5. Pollution removal range: bacteria, viruses and other microorganisms, aerosol DNA / RNA, formaldehyde, benzene, hydrogen sulfide and other harmful gases.
6. Space disinfection purpose, low concentration of hydrogen peroxide (≤8%) can achieve 99.9% killing effect of bacteria.
7. The reagent usage is small, only 6-10mL / m³, the material compatibility is good, no residue, no corrosion.
8. Four air outlets, disinfection without blind angle.
9. The production enterprise has the ISO13485 quality management system certificate.
10. The production enterprise passed the German TUV Rheinland certification.
11. The product has the functions of delayed start, wireless remote control, data recording etc.
12. Turbo-driven nano-micron liquid beads, up to 25m³ / min.
Modello Tipo | NC1001 / NC1002. | ProdottoTipo | sterilizzatore |
nome del prodotto | Strumento di rimozione dell'inquinamento aerosol dell'acido nucleico | Misurare | 560*560*1200 mm |
Il peso | 65 kg. | Consumabili applicabili | Reagente per la rimozione dell'inquinamento dell'aerosol dell'acido nucleico |
Alimentazione elettrica | 220 V. | Interfaccia di comunicazione | USB |
Conclusione:
I risultati del gruppo di controllo hanno dimostrato che il laboratorio ha avuto la contaminazione aerosol plasmica aerosol della febbre suina africana, e il valore TC del controllo negativo era intorno al 26.
Dopo che la contaminazione dell'aerosol viene cancellata, il valore CT del controllo negativo è> 35, che soddisfa lo standard di giudizio negativo (valore CT> 35) del kit di rilevamento.
Il tasso di autorizzazione aerosol è superiore al 99,9% calcolando il valore CT.
Conclusione:
I risultati del gruppo di controllo hanno dimostrato che il laboratorio ha avuto la contaminazione aerosol del plasmide della febbre pappagallo e il valore di controllo negativo della CT è stato circa 35.
Dopo che la contaminazione dell'aerosol viene cancellata, il valore CT del controllo negativo è> 35, che soddisfa lo standard di giudizio negativo (valore CT> 35) del kit di rilevamento.
Il tasso di autorizzazione aerosol è superiore al 99,9% calcolando il valore CT.
Avvertenza calda: questo prodotto non è disponibile per il mercato statunitense.
The air purification sterilizer (nucleic acid aerosol pollution removal instrument) is specially used to remove aerosol DNA / RNA in the laboratory air,
and can also sterilize the space area where the microbial limit is required, which can directly kill bacteria, fungi, viruses, etc. Species of microorganisms.
Qualifica del prodotto
CE Certification/ Test Report-NC1001/ Test Report/ New product and new technology appraisal and acceptance certificate/Electrical safety report/ Disinfection Products Record/ Hygiene License/ ISO 13485 Certificate-MDSAP/ ISO 9001 Certificate/ ISO 45001 Certificate/ ISO 14001 Certificate/ IPMS Certificate/ Verified Supplier Certificate
1. Removal of aerosol DNA / RNA in the air, the removal efficiency reaches more than 99%.
2. No need for air compressor to avoid huge noise.
3. The product adopts a specially designed industrial-grade dispersion system, the diameter of nano-micron liquid beads is ≤5μm.
4. Equipped with HEPA high-efficiency filter to remove residual viruses, bacteria, DNA, RNA and residual reagents effectively in the air.
5. Pollution removal range: bacteria, viruses and other microorganisms, aerosol DNA / RNA, formaldehyde, benzene, hydrogen sulfide and other harmful gases.
6. Space disinfection purpose, low concentration of hydrogen peroxide (≤8%) can achieve 99.9% killing effect of bacteria.
7. The reagent usage is small, only 6-10mL / m³, the material compatibility is good, no residue, no corrosion.
8. Four air outlets, disinfection without blind angle.
9. The production enterprise has the ISO13485 quality management system certificate.
10. The production enterprise passed the German TUV Rheinland certification.
11. The product has the functions of delayed start, wireless remote control, data recording etc.
12. Turbo-driven nano-micron liquid beads, up to 25m³ / min.
Modello Tipo | NC1001 / NC1002. | ProdottoTipo | sterilizzatore |
nome del prodotto | Strumento di rimozione dell'inquinamento aerosol dell'acido nucleico | Misurare | 560*560*1200 mm |
Il peso | 65 kg. | Consumabili applicabili | Reagente per la rimozione dell'inquinamento dell'aerosol dell'acido nucleico |
Alimentazione elettrica | 220 V. | Interfaccia di comunicazione | USB |
Conclusione:
I risultati del gruppo di controllo hanno dimostrato che il laboratorio ha avuto la contaminazione aerosol plasmica aerosol della febbre suina africana, e il valore TC del controllo negativo era intorno al 26.
Dopo che la contaminazione dell'aerosol viene cancellata, il valore CT del controllo negativo è> 35, che soddisfa lo standard di giudizio negativo (valore CT> 35) del kit di rilevamento.
Il tasso di autorizzazione aerosol è superiore al 99,9% calcolando il valore CT.
Conclusione:
I risultati del gruppo di controllo hanno dimostrato che il laboratorio ha avuto la contaminazione aerosol del plasmide della febbre pappagallo e il valore di controllo negativo della CT è stato circa 35.
Dopo che la contaminazione dell'aerosol viene cancellata, il valore CT del controllo negativo è> 35, che soddisfa lo standard di giudizio negativo (valore CT> 35) del kit di rilevamento.
Il tasso di autorizzazione aerosol è superiore al 99,9% calcolando il valore CT.